headerdesktop cve26iun25

MAI SUNT 00:00:00:00

MAI SUNT

X

headermobile cve26iun25

MAI SUNT 00:00:00:00

MAI SUNT

X

Introduction to Power System Protection

Introduction to Power System Protection - Hidaia Mahmood Alassouli

Introduction to Power System Protection


Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. System-protection components have the following design criteria: - Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. - Selectivity: Avoid unnecessary, false trips. - Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. - Economy: Provide maximum protection at minimum cost. - Simplicity: Minimize protection equipment and circuitry. Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.
Citeste mai mult

-10%

transport gratuit

PRP: 194.27 Lei

!

Acesta este Pretul Recomandat de Producator. Pretul de vanzare al produsului este afisat mai jos.

174.84Lei

174.84Lei

194.27 Lei

Primesti 174 puncte

Important icon msg

Primesti puncte de fidelitate dupa fiecare comanda! 100 puncte de fidelitate reprezinta 1 leu. Foloseste-le la viitoarele achizitii!

Livrare in 2-4 saptamani

Descrierea produsului


Power system protection systems have three basic components: Instrument transformers, Relays, Circuit breakers The function of the CT is to reproduce in its secondary winding a current I' that is proportional to the primary current I. The CT converts primary currents in the kiloamp range to secondary currents in the 0-5 ampere range for convenience of measurement. The function of the relay is to discriminate between normal operation and fault conditions. The OC relay in Figure 2 has an operating coil, which is connected to the CT secondary winding, and a set of contacts. When I' exceeds a specified ''pickup'' value, the operating coil causes the normally open contacts to close. When the relay contacts close, the trip coil of the circuit breaker is energized, which then causes the circuit breaker to open. System-protection components have the following design criteria: - Reliability: Operate dependably when fault conditions occur, even after remaining idle for months or years. Failure to do so may result in costly damages. - Selectivity: Avoid unnecessary, false trips. - Speed: Operate rapidly to minimize fault duration and equipment damage. Any intentional time delays should be precise. - Economy: Provide maximum protection at minimum cost. - Simplicity: Minimize protection equipment and circuitry. Since it is impossible to satisfy all these criteria simultaneously, compromises must be made in system protection. The book consists from the following sections: 1. Chapter 1: Power System Faults: 2. Chapter 2: Instrument Transformers. 3. Chapter 3: Overcurrent and Earth Fault Protection Relays. 4. Chapter 4: Radial System Protection. 5. Chapter 5: Zones of Protection. 6. Chapter 6: Differential Relays. 7. Chapter 7: Distance Relays. 8. Chapter 8: Transformer Protection. 9. Chapter 9: Generator Protection. 10. Chapter 10: Busbar Protection. 11. Chapter 11: Circuit Breakers. 12. Chapter 12: Fuses. 13. Chapter 13: References.
Citeste mai mult

S-ar putea sa-ti placa si

De acelasi autor

Parerea ta e inspiratie pentru comunitatea Libris!

Istoricul tau de navigare

Acum se comanda

Noi suntem despre carti, si la fel este si

Newsletter-ul nostru.

Aboneaza-te la vestile literare si primesti un cupon de -10% pentru viitoarea ta comanda!

*Reducerea aplicata prin cupon nu se cumuleaza, ci se aplica reducerea cea mai mare.

Ma abonez image one
Ma abonez image one